SST4566 is a square protective sleeve specifically designed for aluminum busbars used in electric vehicle charging. It is woven by blending polyester multifilaments and monofilaments. It’s orange color facilitates the identification of high-voltage wire harnesses, and it features properties such as wear resistance, corrosion resistance, and easy installation. The product can be customized according to customer requirements and can be enhanced with electromagnetic shielding performance.
The Aluminium Busbar Wrap-SST4566 is a square protective sleeve woven from polyester multifilament and monofilament, engineered for rectangular aluminium busbars in EV charging systems. Standard round sleeving creates edge gaps on flat-sided busbar profiles, leaving abrasion weak points over thousands of connection cycles. The Aluminium Busbar Wrap-SST4566 addresses this: its square cross-section conforms to the busbar geometry, delivering continuous circumferential coverage from installation through the service life.
| Test Item | Test Method | Test Result |
| Impact test after thermal aging | 175°C, 336 hours | No cracking or degradation |
| Abrasion resistance | ISO 6722-1 | Class 6, 30,000 abrasion cycles |
| Flammability | FMVSS 302 | Pass — self-extinguishing after flame removal |
| Operating temperature range | — | –40°C to 150°C |
All listed values are typical test results. For specific product test reports, please consult your sales representative.
The Aluminium Busbar Wrap-SST4566 achieves ISO 6722-1 Class 6 abrasion resistance, sustaining more than 30,000 abrasion cycles. Unlike a standard nylon abrasion sleeve rated for round cable profiles, this woven polyester sleeve maintains tight contact across flat busbar faces and curved transitions. From a wire harness engineering perspective, Class 6 abrasion resistance reflects realistic vibration and contact-loading conditions over the vehicle's service life. Abrasion failures in high-vibration installation zones accumulate progressively, making the abrasion class rating a meaningful service-life indicator for busbar protection selection.
The Aluminium Busbar Wrap-SST4566 operates across –40°C to 150°C, covering both ends of the thermal spectrum encountered in EV charging infrastructure. The lower limit is particularly important for cold-climate deployments: low-temperature embrittlement is an easy checkpoint to overlook during lab-environment testing, but sleeve materials that become brittle at –40°C can crack during winter installation. Confirming low-temperature flexibility with a sample test before bulk procurement for cold-region projects is a practical validation step that the verified –40°C lower limit supports.
The Aluminium Busbar Wrap-SST4566 passes the FMVSS 302 automotive flammability test and is self-extinguishing after flame removal. In high-voltage busbar applications, flammability compliance is a mandatory certification requirement, not an optional upgrade. Selecting busbar protection without first confirming FMVSS 302 status and encountering non-compliance during a supplier qualification audit forces material reselection, creating schedule risk and documentation rework. Documenting FMVSS 302 compliance at the product level from the initial selection stage eliminates this risk downstream.
The Aluminium Busbar Wrap-SST4566 resists gasoline and engine chemicals, suitable for busbar routing near engine compartments and oily environments. This chemical resistance functions as an inert outer barrier — contact with engine fluids does not degrade the sleeve's mechanical integrity or cause swelling that would alter its fit against the busbar profile. This property is relevant for EV charging busbars routed through enclosures that share space with thermal management fluid lines.
| Part No. | Width (mm) | Height (mm) | Thickness (mm) | Overlap (mm) | Cut Length (mm) |
| SST45660825 | 32 ± 2 | 7 +2/–0 | 0.8 ± 0.2 | 8 | Customized |
| SST45660925 | 32 ± 2 | 14 +3/–0 | 0.8 ± 0.2 | 8 | Customized |
| SST45661025 | 40 ± 2 | 8 +2/–0 | 0.8 ± 0.2 | 8 | Customized |
| SST45661225 | 32 ± 2 | 18 +3/–0 | 0.8 ± 0.2 | 8 | Customized |
| SST45661325 | 38 ± 2 | 14 +3/–0 | 0.8 ± 0.2 | 8 | Customized |
| SST45661425 | 38 ± 2 | 18 +3/–0 | 0.8 ± 0.2 | 8 | Customized |
*Cut length customizable per project. Additional sizes available on request.
In EV charging stations and charging gun assemblies, the Aluminium Busbar Wrap-SST4566 provides orange high-voltage identification and FMVSS 302-certified flammability protection for high-voltage aluminium busbars. The orange exterior enables maintenance technicians to identify high-voltage components immediately without additional marking. The wrap-around closure allows installation on busbars already routed in place, without component disassembly — a practical advantage during field service and maintenance replacement.
For new energy vehicle battery packs and stationary energy-storage systems, the Aluminium Busbar Wrap-SST4566 protects aluminium busbars interconnecting cell modules and battery management interfaces. The –40°C to 150°C operating range covers the thermal envelope of battery pack environments. For configurations where busbar dimensions vary across module rows, the six standard part numbers spanning different width and height combinations allow the same sleeve family to address multiple connection points within a single pack design.
High-voltage distribution boxes and PDUs route aluminium busbars in close proximity to adjacent busbars and grounded enclosures, where short-circuit prevention and abrasion resistance are both critical. The Aluminium Busbar Wrap-SST4566 delivers ISO 6722-1 Class 6 abrasion protection against vibration-induced contact wear. Its tight conformance to the square busbar cross-section eliminates edge gaps that round sleeving introduces on rectangular profiles, delivering consistent protection across the full busbar surface.
Key differentiating characteristics of the Aluminium Busbar Wrap-SST4566 for EV busbar protection:
SST4566 is a square protective sleeve specifically designed for aluminum busbars used in electric vehicle charging. It is woven by blending polyester multifilaments and monofilaments. It’s orange color facilitates the identification of high-voltage wire harnesses, and it features properties such as wear resistance, corrosion resistance, and easy installation. The product can be customized according to customer requirements and can be enhanced with electromagnetic shielding performance.