silicone-fiberglass-fire-proof-tube-sft1500775, silicone-fiberglass-fire-proof-tube-sft1500775, /braided-sleeving
Inquiry
silicone-fiberglass-fire-proof-tube-sft1500775, silicone-fiberglass-fire-proof-tube-sft1500775, 
Inquiry

Silicone Fiberglass Fire-proof Tube-SFT1500

SFT1500 utilizes an alkali-free fiberglass braid with iron oxide red silicone coating. Significantly thicker than standard insulation sleeves, it blocks 1650°C short-term thermal spikes while delivering exceptional fireproofing, flame retardancy, thermal insulation, chemical/acid resistance, and anti-aging properties.

Request a Quote
  • Overview

Overview

Silicone Fiberglass Fire-proof Tube-SFT1500: Product Overview

The Silicone Fiberglass Fire-proof Tube-SFT1500 is a heavy-duty industrial cable protection sleeve built with an alkali-free fiberglass braid interior and an iron oxide red silicone rubber exterior. This fiber-inside, silicone-outside dual-layer construction delivers six protective properties in one product: fireproofing, flame retardancy, thermal insulation, heat preservation, acid and alkali resistance, and anti-aging performance. Engineers specifying cable protection for steel mills, EV battery packs, rail transit, and high-voltage power systems will find that each performance claim in the Silicone Fiberglass Fire-proof Tube-SFT1500 is supported by documented test results across multiple internationally recognized standards.

Validated Technical Performance

The Silicone Fiberglass Fire-proof Tube-SFT1500 has been tested against multiple internationally recognized standards:

  • Flammability (SAE J369): VW-1 vertical-burn classification—the most demanding flame rating under this standard.
  • Thermal Conductivity (ASTM E1530): Pass.
  • Dielectric Strength (EN 6059-501:2010, ASTM D3755-20): Average 7,000V; individual minimum 6,000V.
  • Thermal Runaway (1,100°C, 20 minutes): Pass—structural integrity maintained under sustained extreme thermal exposure.

For high-voltage EV and energy storage wiring harnesses, VW-1 flame classification combined with 6,000V minimum dielectric strength addresses both flame containment and electrical isolation requirements from a single sleeve. Test standards vary by industry: SAE J369 is referenced in automotive and industrial applications; rail transit and power infrastructure projects may specify different compliance frameworks.

Key Technical Features

Wide Continuous Operating Range

Stable from -70°C to +260°C continuously, the Silicone Fiberglass Fire-proof Tube-SFT1500 eliminates the need for separate products in cold-environment installation and high-temperature cable runs within the same project.

1,650°C Thermal Spike Resistance

Without melt-through or structural collapse, the SFT1500 provides the safety margin needed for cable runs exposed to molten metal splash, open flame, or direct contact with high-temperature surfaces in steel, glass, and foundry environments.

Heavy-Duty Wall Construction

Wall thickness from 1.8 mm to 5.7 mm depending on the selected ID. When specifying fiberglass cable sleeves, define wall thickness tolerance and incoming measurement method in the purchase order—discrepancies between stated and measured wall thickness are a recurring cause of incoming inspection disputes.

Six-Property Integrated Protection

One sleeve covering fireproofing, flame retardancy, thermal insulation, heat preservation, acid and alkali resistance, and anti-aging reduces insulation SKU count for projects spanning multiple hazard types.

Multi-Certification Facility

ISO 9001, IATF 16949, ISO 14001, ISO 45001, and Military GJB9001C certified. Formal VW-1 flammability documentation is available for EV harness supplier qualification audits—covering both automotive quality management and defense procurement requirements in a single supplier.

Application Scenarios

Steel, Metallurgy, and Glass Manufacturing

Molten metal splash and radiant heat in these environments exceed the limits of standard insulation. The Silicone Fiberglass Fire-proof Tube-SFT1500 provides a VW-1 flame classification and 1,650°C thermal spike tolerance with documented test backing. Cable insulation showing visible color deepening or surface hardening in high-temperature zones is a sign of thermal oxidation aging—the silicone coating in the SFT1500 resists this degradation under normal industrial operating conditions.

EV Battery Packs and High-Voltage Wiring

Battery pack harnesses require both thermal runaway containment and dielectric isolation under normal high-voltage operation. The SFT1500 passes the 1,100°C/20-minute thermal runaway protocol and maintains a 6,000V individual minimum dielectric value—addressing both requirements for EV and stationary energy storage applications.

Rail Transit and Power Substations

Metro, high-speed rail, and transformer station installations require cable protection with long service life and minimal maintenance access. Chemical corrosion resistance, ozone resistance, and anti-aging properties meet the multi-decade reliability requirements of grid and rail infrastructure. Busbar systems in distribution cabinets also benefit from the SFT1500's combined electrical insulation and flame protection.

How the Silicone Fiberglass Fire-proof Tube-SFT1500 Compares to Standard Heat Shrink

Standard heat shrink formats—including dual wall heat shrink tubing and 1/2 inch heat shrink tubing—provide basic cable sealing for moderate environments. The Silicone Fiberglass Fire-proof Tube-SFT1500 addresses three requirements these products are not designed to meet: 1,650°C thermal spike tolerance, formal VW-1 flame classification, and 6,000V minimum dielectric strength in one sleeve. For applications that do not require any of these properties, standard heat shrink remains the appropriate and cost-effective choice.

Specifications

Silicone Fiberglass Fire-proof Tube-SFT1500 — fiber inside, silicone outside. Supplied in 20 m reels. Custom lengths and non-standard inner diameters available on request.

Part No. Nominal I.D. (mm) Thickness (mm) Reel Length (m/reel)
SFT150000607 6.0 ± 1.0 1.8 ± 0.2 20
SFT150000807 8.0 ± 1.0 1.9 ± 0.2 20
SFT150001007 10.0 ± 1.0 2.0 ± 0.2 20
SFT150001307 13.0 ± 1.0 2.1 ± 0.2 20
SFT150001507 15.0 ± 1.0 2.2 ± 0.2 20
SFT150001707 17.0 ± 1.0 2.3 ± 0.2 20
SFT150001907 19.0 ± 1.0 2.4 ± 0.2 20
SFT150002007 20.0 ± 1.0 2.6 ± 0.2 20
SFT150002207 22.0 ± 1.0 2.7 ± 0.2 20
SFT150002507 25.0 ± 1.0 2.8 ± 0.2 20
SFT150002807 28.0 ± 1.0 3.0 ± 0.3 20
SFT150003007 30.0 ± 1.0 3.0 ± 0.3 20
SFT150003207 32.0 ± 1.5 3.1 ± 0.3 20
SFT150003507 35.0 ± 1.5 3.2 ± 0.3 20
SFT150003807 38.0 ± 1.5 3.3 ± 0.3 20
SFT150004007 40.0 ± 1.5 3.4 ± 0.3 20
SFT150004507 45.0 ± 1.5 3.5 ± 0.4 20
SFT150004807 48.0 ± 1.5 3.5 ± 0.4 20
SFT150005007 50.0 ± 2.0 3.7 ± 0.4 20
SFT150005507 55.0 ± 2.0 3.7 ± 0.4 20
SFT150006007 60.0 ± 2.0 3.8 ± 0.4 20
SFT150006507 65.0 ± 2.0 3.9 ± 0.4 20
SFT150007007 70.0 ± 2.0 4.0 ± 0.4 20
SFT150007507 75.0 ± 2.0 4.1 ± 0.4 20
SFT150008007 80.0 ± 2.5 4.2 ± 0.4 20
SFT150008507 85.0 ± 2.5 4.3 ± 0.4 20
SFT150009007 90.0 ± 2.5 4.4 ± 0.5 20
SFT150009507 95.0 ± 2.5 4.5 ± 0.5 20
SFT150010007 100.0 ± 2.5 4.6 ± 0.5 20
SFT150010507 105.0 ± 2.5 4.7 ± 0.5 20
SFT150011007 110.0 ± 3.0 4.8 ± 0.5 20
SFT150011507 115.0 ± 3.0 4.9 ± 0.5 20
SFT150012007 120.0 ± 3.0 5.0 ± 0.55 20
SFT150012507 125.0 ± 3.0 5.1 ± 0.5 20
SFT150013007 130.0 ± 3.0 5.2 ± 0.5 20
SFT150014007 140.0 ± 4.0 5.4 ± 0.5 20
SFT150015007 150.0 ± 4.0 5.6 ± 0.5 20
SFT150015507 155.0 ± 4.0 5.7 ± 0.5 20

Silicone Fiberglass Fire-proof Tube-SFT1500

SFT1500 utilizes an alkali-free fiberglass braid with iron oxide red silicone coating. Significantly thicker than standard insulation sleeves, it blocks 1650°C short-term thermal spikes while delivering exceptional fireproofing, flame retardancy, thermal insulation, chemical/acid resistance, and anti-aging properties.

Request a Quote

Featured Products

silicone fiberglass fire proof tube sft1500775-1

Get a Free Quote

Our representative will contact you soon.
Email
WhatsApp
Mobile
Name
Company Name
Position
Message
0/1000