CR-BS-5003 is made of a mixture of polyester monofilament and tin plated copper foil wire. The overall structure is mainly composed of tin-plated copper foil wire. The weight of the tin-plated copper foil wire is half that of the tin-plated copper wire, effectively reducing the weight while also having excellent electromagnetic shielding function. The side opening structure is easy to install and maintain.
Download Product Manual:
Tinned Copper Foil Self-closing Wrap-CR-BS-5003 is a side-opening braided sleeve designed for cable and wire-harness protection where electromagnetic-interference shielding and practical service access both matter. The product summary identifies a construction that combines polyester monofilament with tin-plated copper foil wire. This construction is intended to provide shielding while helping reduce weight compared with a tin-plated copper-wire alternative described in the existing product material. The self-closing opening allows the sleeve to be wrapped around an assembled harness rather than requiring the harness to be threaded through a closed tube. That distinction can be useful when access is limited, when a harness is already terminated, or when later inspection and maintenance are expected.
Shielding performance depends on diameter, coverage, overlap, routing, grounding, connector interfaces, and installation quality. Confirm the system boundary before selecting the material and installation method.
The existing product information describes Tinned Copper Foil Self-closing Wrap-CR-BS-5003 as a mixture of polyester monofilament and tin-plated copper foil wire, with tin-plated copper foil wire forming the main overall structure. The combination supports a flexible braided construction while retaining the conductive material needed for an EMI-shielding application. Its side-opening format is the defining installation feature: the sleeve can be placed around a cable bundle and allowed to close around it. This makes the product relevant for assemblies that cannot conveniently be passed through a conventional closed sleeve after connectors, branches, or other components have been installed.
Existing page content states a shielding-effectiveness value greater than 60 dB from 30 MHz to 3 GHz under GB/T 30142, an operating-temperature range of -50°C to 150°C, and a UL94 V-0 flame-retardancy classification. These are important selection data points, but they should be confirmed against the applicable current specification and test documentation before being used as release criteria for a particular program. A quoted laboratory result is not a substitute for validating the completed harness, because the overlap and assembly method can affect the installed result.
It is tempting to treat a higher shielding figure as the whole decision. That is too simple. A more useful question is whether the installed sleeve, closure, overlap, grounding path, and affected frequency range fit the system requirement. Where the harness is exposed to movement, tight bends, or regular service, evaluate those mechanical conditions alongside the electrical objective.
The supplied page lists standard nominal inside-diameter options of 8, 10, 13, 16, 19, 25, 30, 38, and 50 mm. Listed applicable harness ranges extend from 5-8 mm for the 8 mm option to 46-60 mm for the 50 mm option. The same source lists a minimum overlap of 30% and reel lengths of 100 m for the smaller listed sizes, 50 m for 19 mm and 25 mm, and 25 m for 30 mm through 50 mm. Use these values as a starting point for selection, then check the current technical document before placing an order or freezing a design.
| Nominal I.D. (mm) | Listed applicable range (mm) | Listed reel length (m) |
| 8 | 5-8 | 100 |
| 10 | 9-11 | 100 |
| 13 | 12-14 | 100 |
| 16 | 15-17 | 100 |
| 19 | 18-21 | 50 |
| 25 | 22-28 | 50 |
| 30 | 29-34 | 25 |
| 38 | 35-44 | 25 |
| 50 | 46-60 | 25 |
Select size from the real harness outer diameter, passage geometry, and target overlap. Check branches and connectors before release.
Tinned Copper Foil Self-closing Wrap-CR-BS-5003 may be considered for vehicle harness routes where electromagnetic compatibility, access, and weight are all evaluated together. High-voltage and control harnesses should not be treated as equivalent: confirm the relevant electrical, thermal, flame, and system-level requirements for each route. For example, a shielding sleeve is not automatically an insulation solution. If the project requires dielectric protection, sealing, or a defined high-voltage rating, verify that requirement separately with the appropriate material and test evidence.
For industrial automation, power-conversion equipment, or control-panel harnesses, the side-opening layout may be useful where existing wiring needs coverage without disassembly. Verify the environmental exposure, bundle geometry, service procedure, and the equipment-level EMC target before final selection. A sleeve that is easy to install can still be a poor fit if the bend path, attachment method, or grounding design is overlooked.
For retrofit work, inspect the harness, identify the sections requiring coverage, and confirm that the selected size closes with the intended overlap. Document the installation method for later review.
Start with the product definition: Tinned Copper Foil Self-closing Wrap-CR-BS-5003 is a self-closing shielding sleeve, not a universal answer to every cable-protection task. Confirm harness diameter, target coverage, allowable overlap, temperature exposure, frequency range, grounding configuration, flame requirement, and service-access needs. Then request the applicable product specification and relevant test records for the specific part and project. The existing page notes that customized cutting and non-standard sizes may be available on request; availability, lead time, and acceptance requirements should be confirmed directly.
Related terms such as 25mm heat shrink tubing and welding cable protective sleeve describe different protection needs and should not be treated as interchangeable with this shielding wrap. Heat-shrink tubing may be evaluated where a shrinkable insulating covering is required, while a protective sleeve for welding cable may require a separate assessment of abrasion, heat, and environmental exposure. Selecting by actual operating conditions rather than by a broad category name is the more reliable approach.
CR-BS-5003 is made of a mixture of polyester monofilament and tin plated copper foil wire. The overall structure is mainly composed of tin-plated copper foil wire. The weight of the tin-plated copper foil wire is half that of the tin-plated copper wire, effectively reducing the weight while also having excellent electromagnetic shielding function. The side opening structure is easy to install and maintain.
Download Product Manual: